50 Person Harlequin HydroClear Sewage Treatment Plant.
  • 50 Person Harlequin HydroClear Sewage Treatment Plant.

50 Person Harlequin HydroClear Sewage Treatment Plant

HQ1106HC50
Harlequin HC50
Within 5-7 Working Days
£14,545.13
£12,120.94 ex. VAT
Quantity:

Product Details

This item is supplied to order and additional refund & returns terms apply.

Specifications

Population Served: 41-50
Nominal Hydraulic Daily Load: 10,000 Litres/day
Nominal Organic Daily Load: 3,000g BOD5/day
Electrical Consumption: 5.8 kWh/day
Blower Rating: 240W
Desludging Interval: 6 months (depending on usage)
Tank 1 Overall Dimensions: L 5680 / W 1400 / H 2560 mm
Tank 2 Overall Dimensions: L 4500 / W 1400 / H 2560 mm
Tank 3 Overall Dimensions: L 3400 / W 1250 / H 2560 mm
Standard Inlet Depth: 1100 mm
Standard Outlet Depth: 1150 mm
Depth from Invert to Base: 1460 mm
Pipe Diameter: 160 mm
Tank 1 Net Weight: 490 kg
Tank 2 Net Weight: 780 kg
Tank 3 Net Weight: 320 kg
Manhole Cover Size: 450mm pedestrian duty

The HydroClear 50 sewage treatment plant is designed to efficiently treat wastewater from bathrooms, toilets, laundry and kitchens for safe discharge into a watercourse, such as a river or a stream, or drainage field with a class-leading BOD pollutant removal level of 97%.

Manufactured from durable Medium Density Polyethylene (MDPE), with a life expectancy of over 20 years, this 3-tank, slim profile system is an ideal off-mains solution for properties with up to 50 inhabitants.

Product Features at a Glance:

  • Durable - Tank bodies moulded in one piece from durable MDPE.
  • Adaptable - Adjustable turrets allowing for shallower invert levels.
  • Reliable - Moving Bed Biofilm Reactor (MBBR) system ensures there is no fixed media which eliminates blockages.
  • Efficient - Pollutant removal level of 97%.
  • Quiet - Equipped with an external blower, conveniently located in a weatherproof aboveground external housing, for optimal performance and quiet operation.
  • Easy Install - Lightweight, slim profile (with integrated lifting eyes) ensures ease of handling and lower installation costs. Fully secured 450mm pedestrian duty flush fitting low-profile manhole cover, 160mm inlet and outlet connections as standard.
  • Low Maintenance - Mechanically reliable, with no moving parts or electrics within the tank, and a 24-month service period reduces operating costs.
  • Fully Compliant - EN12566-3 certified for use in the UK.
  • 2-Year Warranty - when product is registered on Harlequin’s website.

The multi-tank design of the HydroClear 50 sewage treatment plant offers a highly flexible solution to sites limited by space. Tank 1 serves the Primary Settlement stage (8440 Litres) while Tank 2 serves the Aeration stage(6600 Litres) and Tank 3 serves Final Settlement stage(4650 Litres).

Treatment Efficiency:

  Efficiency Effluent
COD 91.2% 59 mg/l
BOD5 96.6% 11 mg/l
NH4-N 85.8% 4.5 mg/l
SS 94.7% 19 mg/l

 

Harlequin Wastewater Management

Harlequin develops innovative wastewater management products for use in the residential, commercial, and agribusiness sectors. With state-of-the-art manufacturing facilities, they engineer a wide range of specialist products, such as wastewater treatment plants, rainwater harvesting systems, and hot water storage systems. Their products are designed and manufactured to exceed the most technical, environmental, and regulatory requirements.

Their HydroClear range of sewage treatment plants offer cost-effective, super quiet effluent solutions for off-mains installations with a pollutant removal level of 97%.

Features & Benefits:

  • Super Quiet - High performance diaphragm blowers are used and externally housed achieving a super quiet operation.
  • Odourless - The system is hermetically sealed to eliminate odour.
  • MBBR Technology - Moving Bed Biological Reactor (MBBR) systems are self-cleaning and unable to become blocked through channelling unlike most fixed film media systems.
  • Market leading performance - Producing an excellent 97% pollutant removal level, the final effluent can be directly discharged into a stream or soakaway.
  • Low Maintenance Costs - Chamber one capacity is as much as 66% larger than other plants, making desludging intervals up to three times longer saving the owner significant costs.
  • Power Failure Default - The system keeps performing as a septic tank in the event of a power failure.

 

Please Note: All images shown are used for illustration purposes only and may differ from the actual product supplied.

SKU:
HQ1106HC50
Availability:
Within 5-7 Working Days
Population:
25+ Persons
Install Type:
Large Capacity
Make:
Harlequin
Product Type:
Sewage Treatment Plant